PXR4(PXV4)
PXR4(PXV4)
双排显示PV、SP等数据
12种热电偶信号、3种热电阻信号、5种线形信号输入
继电器输出、电压、电流信号输出
带手/自动模式,切换便利
多种辅助输出功能
多种控制算法输出:ON/OFF、PID、双重(冷热区)输出、马达阀门控制,单相/三相可控硅控制
三路(可选)报警输出,17种报警类型
8段设定点程序
满量程0.5%精度,EEROM非易失性内存,确保数据在掉电情况下不会丢失
85-256Vac/50(60)HZ供电工作
|
PXR4系列选型说明 |
||||||||||||
|
数字位 |
规格 |
代号 |
|
|||||||||
|
4 |
5 |
6 |
7 |
8 |
- |
9 |
10 |
11 |
12 |
13 |
||
|
4 |
面板尺寸 H*W |
|
|
|
|
|
|
|
|
|
|
|
|
48*48 |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
5 |
输入信号 |
|
|
|
|
|
|
|
|
|
|
|
|
热电偶(℃) |
|
T |
|
|
|
|
|
|
|
|
|
|
|
热电偶(F) |
|
R |
|
|
|
|
|
|
|
|
|
|
|
RTD/PT100(℃) |
|
N |
|
|
|
|
|
|
|
|
|
|
|
RTD/PT100(F) |
|
S |
|
|
|
|
|
|
|
|
|
|
|
1~5V DC |
|
A |
|
|
|
|
|
|
|
|
|
|
|
4~20mA DC |
|
B |
|
|
|
|
|
|
|
|
|
|
|
6 |
控制输出1 |
|
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出 |
|
|
A |
|
|
|
|
|
|
|
|
|
|
SSR/SSC驱动输出 |
|
|
C |
|
|
|
|
|
|
|
|
|
|
4~20mA DC输出 |
|
|
E |
|
|
|
|
|
|
|
|
|
|
7 |
控制输出2 |
|
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
Y |
|
|
|
|
|
|
|
|
|
继电器接点输出 注1 |
|
|
|
A |
|
|
|
|
|
|
|
|
|
SSR/SSC驱动输出 注1 |
|
|
|
C |
|
|
|
|
|
|
|
|
|
4~20mA DC输出 注1 |
|
|
|
E |
|
|
|
|
|
|
|
|
|
再传输出(4-20Ma DC) |
|
|
|
R |
|
|
|
|
|
|
|
|
|
8 |
版本号 |
|
|
|
|
1 |
- |
|
|
|
|
|
|
9 |
附加功能1 |
|
|
|
|
|
|
|
|
|
|
|
|
无报警 |
|
|
|
|
|
|
0 |
|
|
|
|
|
|
1个报警 |
|
|
|
|
|
|
1 |
|
|
|
|
|
|
加热器断路报警 注3 |
|
|
|
|
|
|
2 |
|
|
|
|
|
|
1个报警+加热器断路报警 注3 |
|
|
|
|
|
|
3 |
|
|
|
|
|
|
8段斜坡/保温程序 |
|
|
|
|
|
|
4 |
|
|
|
|
|
|
1个报警+8段斜坡/保温程序 |
|
|
|
|
|
|
5 |
|
|
|
|
|
|
加热器断路报警+8段斜坡/保温程序注3 |
|
|
|
|
|
|
6 |
|
|
|
|
|
|
1个报警+加热器断路报警+8段斜坡/保温程序 注3 |
|
|
|
|
|
|
7 |
|
|
|
|
|
|
两个报警 |
|
|
|
|
|
|
F |
|
|
|
|
|
|
两个报警+8段斜坡/保温 |
|
|
|
|
|
|
G |
|
|
|
|
|
|
2个报警+加热器断路报警+8段斜坡/保温程序 注3 |
|
|
|
|
|
|
H |
|
|
|
|
|
|
3个报警 |
|
|
|
|
|
|
M |
|
|
|
|
|
|
遥控设定 注3 |
|
|
|
|
|
|
D |
|
|
|
|
|
|
遥控设定+2个报警 注3 |
|
|
|
|
|
|
P |
|
|
|
|
|
|
10 |
操作说明书 电源电压 |
|
|
|
|
|
|
|
|
|
|
|
|
无 100-240V |
|
|
|
|
|
|
|
N |
|
|
|
|
|
日文 100-240V |
|
|
|
|
|
|
|
Y |
|
|
|
|
|
英文 100-240V |
|
|
|
|
|
|
|
V |
|
|
|
|
|
无 24VAC/24VDC |
|
|
|
|
|
|
|
C |
|
|
|
|
|
日文 24VAC/24VDC |
|
|
|
|
|
|
|
A |
|
|
|
|
|
英文 24VAC/24VDC |
|
|
|
|
|
|
|
B |
|
|
|
|
|
11 12 13 |
附加功能2 |
|
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
|
|
|
|
|
0 |
0 |
0 |
|
|
RS485 (MODBUS)通讯 |
|
|
|
|
|
|
|
|
M |
0 |
0 |
|
|
RS485 (Z-ASC11)通讯 |
|
|
|
|
|
|
|
|
N |
0 |
0 |
|
|
1点数字输入 |
|
|
|
|
|
|
|
|
Q |
0 |
0 |
|
|
2点数字输入 注4 |
|
|
|
|
|
|
|
|
T |
0 |
0 |
|
|
RS485(MODBUS)通讯+1点数字输入 |
|
|
|
|
|
|
|
|
V |
0 |
0 |
|
|
RS485(Z-ASC11)通讯+1点数字输入 |
|
|
|
|
|
|
|
|
W |
0 |
0 |
|
|
注1:输出4-20mA 不能与加热器断路报警一起选.(即选项9中的2、3、6、7) |
||||||||||||
|
注2:不能和1个报警+加热器断路报警或两个报警一起选。(即选项9中的3、7、F、G、H) |
||||||||||||
|
注3:不能与RS485+1点数字输入一起选。(即选项11、12、13中的V00) |
||||||||||||
|
注4:若选择2点数字输入,输出2或加热器断路报警不能选。 |
||||||||||||